Parker THM Analyzer VPH-THM-1000

Product Detail

< Back

Parker THM Analyzer VPH-THM-1000

The Parker Hannifin's THM-1000 Analyzer is a drinking water disinfection by product monitor, that allows you to quickly measure Trihalomethanes (THM) in water, ensuring water is safe to drink, without any off-site analysis or even sample preparation.

Very easy to use, it measures THM concentration at ppb levels in less than 30 minutes, in situ, thanks to its integrated purge and trap Gas Chromatograpgh (GC). This integrated system will help you optimize water treatment at the plant and evaluate water age in the distribution system for improved control over the formation of THMs.

Main Features:

30 minute analysis
User-friendly interface with push button simplicity
All in one purge and trap system: sample purging, component separation and data analysis
Rapid operator feedback, allowing for immediate process adjustment

Applications:Local Water Plants, Universities, Beverage Plants, Research, amongst others. Read the application note on how the THM AnalyZer helped Anglian Water optimise water treatment.

The THM comes complete with Surface Acoustic Wave (SAW) based detector for THM measurement Laptop Computer, which includes Preloaded THM Analyzer Software.

Also included is: Quick Start Guide Certificate of Calibration from Factory, the Glass Sample Holder (2), Spare Pre Concentrator (1), Pre Concentrator Extraction Tool (1), 1/8 Diameter Teflon Tubing (25’), 1/8 A-LOK Fittings (6). The Analyzer and Laptop inlcude 1-year parts & labour warranty. Note: RoHS Compliant, Lead Free Chassis.

Technical Specifications
Length: 15.8" | 401mm
Height: 15.3" | 389mm
Width (inch): 9.4" | 239mm
Weight (kg): 7.5
Weight (lbs): 16.5
Voltage (vdc): 24
Voltage (vac): 120
Power supply: Universal ac input, 24 VDC internal
Certificates: ETL 61010, FCC part 15 Class A, ETL, CE
Wattage (w): 220-240
Measured Compounds: Chloroform, Dichlorobromomethane, Dibromochloromethane, Bromoform
Average Measurement Time: Less than 30 minutes
Accuracy: Total THM: 10% (Standard factory calibration)
Precision: Total THM: ±5% RSD
Calibration: External calibration
Factory Calibration Range: 2ppb to 80ppb for each compound
Sampling and Analysis Time: Approximately 30 minutes
Detector Type: Surface Acoustic Wave (SAW) sensorinternal
Carrier Gas: UHP grade helium
Carrier Gas Supply Pressure: 55 – 60 psig (3.8 – 4.1 bar)
Total Gas Volume Consumed per Measurement Cycle: 0.04 ft3 (Up to 4,000 cycles from a single 300 cubic foot high pressure cylinder (DOT 3AA2400))
Water Sample Volume: 40 ml
Recommended Operating Temperature Range: 68ºF to 85ºF (20ºC to 30ºC)
Storage Temperature Range: 5ºC to 40ºC (41°F to 104°F)
Relative Humidity: < 90% (non-condensing)
Operating the Analyzer within the recommended ranges ensures optimum instrument performance.