Photometric test kit for measurement of COD Chemical oxygen demand O2
Available ranges:
500 -10000 mg/l COD (sample preparation in thermoreactor required, 148 °C, 2 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Applications:
Wastewater, production control, ground water, surface water
Storage:
Store away from light!
Note:
For C3/25 CombiCheck 10 can be used, for C4/25 CombiCheck 20 can be used
Photometric test kit for measurement of COD Chemical oxygen demand O2
Available ranges:
300 - 3500 mg/l COD (sample preparation in thermoreactor required, 148 °C, 2 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 2ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Applications:
Wastewater, production control, ground water, surface water
Storage:
Store away from light!
Note:
For C3/25 CombiCheck 10 can be used, for C4/25 CombiCheck 20 can be used
Photometric test kit for measurement of COD Chemical oxygen demand O2
Available ranges:
15 - 300 mg/l COD (sample preparation in thermoreactor required, 148 °C, 2 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 2ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Applications:
Wastewater, production control, ground water, surface water
Storage:
Store away from light!
Note:
For C3/25 CombiCheck 10 can be used, for C4/25 CombiCheck 20 can be used
Photometric test kit for measurement of Total Nitrogen NTotal
Number of tests: 50 (Cuvette Test)
Sample volume required: 2; 2ml
Compatible with photometers:
pHotoFlex 0 - 25.0 mg/l NTotal(120°C, 30 min.)
Additional information:
Reaction:
Koroleff digestion (oxidation to nitrate, analog to DIN EN ISO 11 905): determination with Nitrospectral (Model 14537) or DMP (Models 14763 and 00613) analog to DIN 38 405 D9 / ISO 7890/1. Models Ntot-1and Ntot-2 TC: digestion with persulfate
Applications:
Wastewater, drinking water, surface water
Note:
All digestion reagents are contained in the test set
Photometric test kit for measurement of Total Nitrogen NTotal
Number of tests: 50 (Cuvette Test)
Sample volume required: 0.5; 2ml
Compatible with photometers:
pHotoFlex 5 - 150 mg/l NTotal(120°C, 30 min.)
Additional information:
Reaction:
Koroleff digestion (oxidation to nitrate, analog to DIN EN ISO 11 905): determination with Nitrospectral (Model 14537) or DMP (Models 14763 and 00613) analog to DIN 38 405 D9 / ISO 7890/1. Models Ntot-1and Ntot-2 TC: digestion with persulfate
Applications:
Wastewater, drinking water, surface water
Note:
All digestion reagents are contained in the test set
Photometric test kit for measurement of COD Chemical oxygen demand O2
Available ranges:
10 - 150 mg/l COD (sample preparation in thermoreactor required, 148 °C, 2 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 3ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 10 - 150 mg/l COD (148 °C, 2 h)
Additional information:
Reference CombiCheck test available.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Applications:
Wastewater, production control, ground water, surface water
Storage:
Store away from light!
Note:
For C3/25 CombiCheck 10 can be used, for C4/25 CombiCheck 20 can be used
Photometric test kit for measurement of COD Chemical oxygen demand O2
Available ranges:
25 - 1500 mg/l COD (sample preparation in thermoreactor required, 148 °C, 2 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 3ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 25 - 1500 mg/l COD (148 °C, 2 h)
Additional information:
Reference CombiCheck test available.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Applications:
Wastewater, production control, ground water, surface water
Storage:
Store away from light!
Note:
For C3/25 CombiCheck 10 can be used, for C4/25 CombiCheck 20 can be used
Photometric test kit for measurement of Water hardness, total hardness
Available ranges:
0.7 - 30.1 °d,
5 - 215 mg/l Ca
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.7 - 30.1 °d, 5 - 215 mg/l Ca
Additional information:
Reaction:
Phthalein complexone
Applications:
Check of ion-exchanger plants for the production of deionized water
LED filter photometer with integrated turbidity and pH function in a field case with table insert to hold instrument, stand and cuvettes; pH electrode SenTix 41 and Pipette KK/VAR5000 with tips, adjustable, 5 ml. Accessories: empty cuvettes 16+28 mm, calibration kit for turbidity, cleaning tissues, stand, buffer solutions pH 4.01 + 7.00, beaker, screw driver, PC cable AK 540 B, instructions
pHotoFlex STD/SET - Portable LED filter photometer with 6 wavelength, 50 user-defined methods and 100 data sets, in a field case with table insert and accessories.
Accessories: Syringe 2 and 10 ml, empty vials 16+28 mm, cleaning tissues, screw driver, PC-software LSdata, PC cable AK 540 B, instructions.
WTW Digital multiparameter benchtop meter with universal single input for IDS sensors, for measurements / documentation according GLP/AQA.
Set including IDS sensor.
Meter with universal power supply, stand and operation manual, optical IDS D.O. sensor FDO® 925, software and USB cable.