Easy-to-operate basic pH/mV benchtop meter with DIN socket for routine measurement.
For AC and battery operation.
Meter with universal power supply, stand and operation manual.
Combined pH electrode SenTix® 81, buffer 4, 7 and 10.01, 3 mol/l KCl
Ammonium Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL NH4 19812
Chloride Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Cl 19897
Chromate Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL CrO3 19780
Photometric test kit for measurement of Ammonium NH4
Number of tests: 50 (Cuvette Test)
Sample volume required: 0.1ml
Compatible with photometers:
pHotoFlex 0 - 50 mg/l NH4-N; 0 - 64 mg/l NH4
Additional information:
Reaction:
Indophenol blue (Berthelot reaction) analog to DIN 38 406 E5/ISO 7150. Models NH4-x: Salyticate
Applications:
Wastewater, drinking water, sea water
LED filter photometer with integrated turbidity measurement and pH functions for field use with optional Lab support via LabStation, single instrument with calibration standard kit (0.02 - 10 - 1000 NTU); optional: rech. batt. (251 300) and LabStation (251 301), pH electrodes see catalog
Photometric test kit for measurement of Total Nitrogen NTotal
Available ranges:
0.5 - 15.0 mg/l NTotal (sample preparation in thermoreactor required, 120 °C, 1 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.5 - 15.0 mg/l NTotal (120 °C, 1 h)
Additional information:
Reference CombiCheck test available.
Reaction:
Koroleff digestion (oxidation to nitrate, analog to DIN EN ISO 11 905): determination with Nitrospectral (Model 14537) or DMP (Models 14763 and 00613) analog to DIN 38 405 D9 / ISO 7890/1. Models Ntot-1and Ntot-2 TC: digestion with persulfate
Applications:
Wastewater, drinking water, surface water
Note:
All digestion reagents are contained in the test set
Aluminium Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Al 19770
Manganese Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Mn 19789
Photometric test kit for measurement of Total Nitrogen NTotal
Available ranges:
10 - 150 mg/l NTotal (sample preparation in thermoreactor required, 120 °C, 1 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
Additional information:
Reference CombiCheck test available.
Reaction:
Koroleff digestion (oxidation to nitrate, analog to DIN EN ISO 11 905): determination with Nitrospectral (Model 14537) or DMP (Models 14763 and 00613) analog to DIN 38 405 D9 / ISO 7890/1. Models Ntot-1and Ntot-2 TC: digestion with persulfate
Applications:
Wastewater, drinking water, surface water
Note:
All digestion reagents are contained in the test set
Photometric test kit for measurement of Chlorine dioxide ClO2
Available ranges:
0.020 - 10.00 mg/l ClO2
Number of tests: 150 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 0.02 - 7.50 mg/l ClO2
Additional information:
Reaction:
DPD, analog DIN 38408 G5
Applications:
Drinking water, wastewater, disinfectants
Note:
Bromine, chlorine, ozone and iodine also react
Photometric test kit for measurement of Total Nitrogen NTotal
Available ranges:
0.5 - 15.0 mg/l NTotal (sample preparation in thermoreactor required, 120 °C, 1 h)
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Koroleff digestion (oxidation to nitrate, analog to DIN EN ISO 11 905): determination with Nitrospectral (Model 14537) or DMP (Models 14763 and 00613) analog to DIN 38 405 D9 / ISO 7890/1. Models Ntot-1and Ntot-2 TC: digestion with persulfate
Applications:
Wastewater, drinking water, surface water
Note: