Refrigerated circulators are suitable for temperature control for internal and external applications. Operation is simple and intuitive via the central rotary knob on the front of the unit.

  • 3.5" TFT colour display with multilingual user interface
  • Integrated programmer for 8 x 60 program steps
  • Easy pump switching between internal and external circulation
  • External pump connections (M16x1)
  • Infinitely adjustable pressure pump
  • USB connection
  • Space-saving cooling coil design yields more usable space in the bath tank
  • External Pt100 connection
  • Stainless steel bath tank including bath lid and drain tap
  • Removable ventilation grid
  • 2 hose olives each suitable for hose inner diameter 8 and 12 mm included
  • Class III (FL) acc. to DIN 12876-1

Refrigerated circulators DYNEO™ DD
Temperature stability:±0.01 °C
Heating capacity:2 kW
Flow rate:8 ... 27 l/min
Pump pressure:0.1 ... 0.7 bar
Timer:0 ... 99 h 59 min

Refrigerated circulators DYNEO™ DD



DYNEO DD-1000F Refrigerated / Heating Circulator Julabo 9 021 707
PART NO.G-9021707
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-1000F||5 ... 7.5||Refrigerant R449A||180 x 130||150||51.2||-50 ... 200||1.0 / 0.96 / 0.51||1
Julabo
9021707

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
12
1
Out of Stock
DYNEO DD-601F Refrigerated / Heating Circulator Julabo 9 021 705
PART NO.G-9021705
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-601F||8 ... 10||Refrigerant R449A||220 x 150||200||38.2||-35 ... 200||0.6 / 0.44 / 0.16||1
Julabo
9021705

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
10
1
Out of Stock
DYNEO DD-600F Refrigerated / Heating Circulator Julabo 9 021 704
PART NO.G-9021704
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-600F||5 ... 7.5||Refrigerant R449A||220 x 150||150||35.7||-35 ... 200||0.6 / 0.44 / 0.16||1
Julabo
9021704

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
9
1
Out of Stock
DYNEO DD-300F Refrigerated / Heating Circulator Julabo 9 021 703
PART NO.G-9021703
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-300F||3 ... 4||Refrigerant R134a||130 x 150||150||27.7||-25 ... 200||0.3 / 0.27 / 0.08||1
Julabo
9021703

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
2
1
Out of Stock
DYNEO DD-201F Refrigerated / Heating Circulator Julabo 9 021 702
PART NO.G-9021702
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-201F||3 ... 4||Refrigerant R134a||130 x 150||150||24.7||-20 ... 200||0.2 / 0.15 / 0.02||1
Julabo
9021702

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
2
1
Out of Stock
DYNEO DD-200F Refrigerated / Heating Circulator Julabo 9 021 701
PART NO.G-9021701
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-200F||3 ... 4||Refrigerant R134a||130 x 150||150||25.7||-20 ... 200||0.2 / 0.15 / 0.02||1
Julabo
9021701

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
0
1
Out of Stock
Julabo DYNEO DD-1200FW Refrigerated/heating circulator 9021728.N1
PART NO.4AJ-4693946
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-1200FW||5 ... 7.5||Natural refrigerant R1270||180 x 130||150||44.0||-50 ... 200||1.24 / 1.09 / 0.62||1
Julabo
9021728.N1
DYNEODD

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
2
15
1
Out of Stock
Julabo DYNEO DD-200F Refrigerated/heating circulator with 9021701.N1
PART NO.4AJ-4693943
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-200F||3 ... 4||Natural refrigerant R290||130 x 150||150||25.7||-20 ... 200||0.2 / 0.15 / 0.02||1
Julabo
9021701.N1
DYNEODD

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
2
1
1
Out of Stock
Julabo Refrigerated/Heating Circulator DYNEO DD-1200F 9021717.N1
PART NO.4AJ-4692241
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-1200F||5 ... 7.5||Natural refrigerant R1270||180 x 130||150||44.0||-50 ... 200||1.24 / 1.09 / 0.62||1
Julabo
9021717.N1
DYNEODD120

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
13
1
Out of Stock
Julabo Refrigerated/Heating Circulator DYNEO DD-800F 9021715.N1
PART NO.4AJ-4692238
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-800F||5 ... 7.5||Natural refrigerant R1270||180 x 130||150||42.0||-40 ... 200||0.84 / 0.74 / 0.39||1
Julabo
9021715.N1
DYNEODD800

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
10
1
Out of Stock
Julabo Refrigerated/heating circulator DYNEO DD-449F 9021716.N1
PART NO.4AJ-4687384
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-449F||21 ... 30||Natural refrigerant R290||230 x 350||200||39.5||-32 ... 200||0.44 / 0.35 / 0.20||1
Julabo
9021716.N1
DYNEODD449

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
12
1
Out of Stock
Julabo Refrigerated/heating circulator DYNEO DD-450F 9 021 714.S1
PART NO.4AJ-4685643
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-450F||3 ... 4||Refrigerant R449A||130 x 150||150||27.4||-30 ... 200||0.44 / 0.37 / 0.16||1
Julabo
9 021 714.S1
DYNEODD450

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
7
1
Out of Stock
Julabo Refrigerated/heating circulator DYNEO DD-450F 9 021 714.N1
PART NO.4AJ-4685640
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-450F||3 ... 4||Natural refrigerant R290||130 x 150||150||27.4||-30 ... 200||0.44 / 0.37 / 0.16||1
Julabo
9 021 714.N1
DYNEODD450

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
7
1
Out of Stock
Julabo Refrigerated/heating circulator DYNEO DD-310F 9 021 713.S1
PART NO.4AJ-4685637
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-310F||3 ... 4||Refrigerant R449A||130 x 150||150||27.4||-30 ... 200||0.3 / 0.27 / 0.12||1
Julabo
9 021 713.S1
DYNEODD310

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
4
1
Out of Stock
Julabo Refrigerated/heating circulator DYNEO DD-310F 9 021 713.N1
PART NO.4AJ-4685634
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-310F||3 ... 4||Natural refrigerant R290||130 x 150||150||27.4||-30 ... 200||0.3 / 0.27 / 0.12||1
Julabo
9 021 713.N1
DYNEODD310

Refrigerated circulator(s) bath(s)

Thermostat(s) circulation

Thermostat(s) cooling

0
0
3
1
Out of Stock
DYNEO DD-1001F Refrigerated / Heating Circulator Julabo 9 021 708
PART NO.G-9021708
73130||18935||18730||73230||73509||73569||73759||73709||73401
Type||Filling volume L||Description||Bath opening mm||Bath tank depth mm||Weight kg||Working Temp. range °C||Cooling capacity kW at 20/0/-20°C||PK
DD-1001F||42 ... 56||Refrigerant R449A||350 x 410||300||73.7||-38 ... 100||1.0 / 0.85 / 0.32||1
Julabo
9021708