Variable piston pipette 100 - 1000 µl (setting adjustable in 1 µl steps)
Variable piston pipette 0.5 - 5 ml with (setting adjustable in 10 µl steps)
Robust, general purpose 4-electrode conductivity cell with graphite electrodes incorporating integral temperature sensor
Memory for 10 calibrations, stored serial number, measuring range 10 µS/cm to 2000 mS/cm ±0.5% of value, 0.0 to 100.0°C
±0.2°C with 1.5m cable.
A combination pH electrode that is used for measurement in polluted samples. It measures pH value of low-ion samples, the smallest of volumes, and much more. This pH electrode includes a polymer electrolyte and is a low maintenance and easy to clean electrode. Key Features:
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M 256 for meters to be used at waste water treatment plants
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 50 um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* Especially suitable for use in denitrification and for oxygen addition measurements
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 25um special membrane
- Extremely short response time
- Low incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 30 seconds
Sensor length:
- 196mm
Connection cable:
- 7m, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Zero current free electrode system
- Exchangeable membrane head with robust 50um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60 mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP65)
Type of protection:
- IP 68 (sensor)
Low maintenance combined pH electrode with ATC
QSC suitable
Memory for 10 calibrations
Stored serial number
pH 0.000 to 14.000 (±0.004 pH)
Temperature range 0.0 to 80.0°C
±0.2°C with 3m cable
Printer paper for P 3001 and inoLab printer, thermal paper legible for approx. 5 years, width 112 mm
Photometric test kit for measurement of Lead Pb
Available ranges:
0.10 - 5.00 mg/l Pb
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
Additional information:
Reference CombiCheck test available.
Reaction:
Pyridylazoresorcinol PAR
Applications:
Wastewater, drinking water
Note:
Falls under the hazardous substances regulations as it contains cyanide. Contains no digestion reagents. For the determination of total lead crack set 10 and empty round or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
Photometric test kit for measurement of Iron Fe
Available ranges:
0.05 - 4.00 mg/l Fe
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.05 -34.00 mg/l Fe
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models 14549 and 14761: Triazine. Model 14896, Model FE-2 TP: 2.2’-dipyridine (differentiation between Fe2+ and Fe3+ possible) analog DIN 38406E1 and US Standard Method 3500-Fe LD; Model FE-1 TP: TPTZ
Applications:
Wastewater, drinking water, foodstuffs
Note:
For the determination of total iron crack set 10 and empty round cuvettes or Crack-Set 10-C are required (120 °C, 1 h)
Photometric test kit for measurement of Iron Fe
Available ranges:
1.0 - 50.0 mg/l Fe
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Models 14549 and 14761: Triazine. Model 14896, Model FE-2 TP: 2.2’-dipyridine (differentiation between Fe2+ and Fe3+ possible) analog DIN 38406E1 and US Standard Method 3500-Fe LD; Model FE-1 TP: TPTZ
Applications:
Wastewater, drinking water, foodstuffs
Note:
For the determination of total iron crack set 10 and empty round cuvettes or Crack-Set 10-C are required (120 °C, 1 h)