Technical buffer solution pH = 10.01; Container with 10 bottles with 1 liter each
Technical buffer solution pH = 10.01; Container with 25 bottles with 1 liter each
Technical buffer solution pH = 10.01; Container with 10 bottles with 250 ml each
Technical buffer solution pH = 10.01; Container with 25 bottles with 250 ml each
Photometric test kit for measurement of Oxygen O2
Available ranges:
0.5 - 12.0 mg/l O2
Number of tests: 25 (Reaction cuvettes test)
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Modified Winkler method
Applications:
Surface water, drinking water
Photometric test kit for measurement of Copper Cu
Available ranges:
0.05 - 8.00 mg/l Cu
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.05 - 7.50 mg/l Cu
Additional information:
Reference CombiCheck test available.
Reaction:
Cuprizon. Model Cu-1 TP: Biquinoline
Applications:
Wastewater, drinking water, ground water, foodstuffs
Note:
Crack set 10 and empty round cuvettes or Crack set 10-C are required for the determination of total copper (100 °C or 120 °C, 1 h)
Photometric test kit for measurement of Nickel Ni
Available ranges:
0.10 - 6.00 mg/l Ni
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Dimethylglyoxime, analog to DIN 38406 E11
Applications:
Wastewater, drinking water, surface water
Note:
For the determination of total nickel crack set 10 and empty round or Crack-Set 10-C are required (120 °C, 1 h)
Photometric test kit for measurement of Iron Fe
Available ranges:
0.005 - 5.00 mg/l Fe
Number of tests: 1000 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.05 - 3.00 mg/l Fe
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models 14549 and 14761: Triazine. Model 14896, Model FE-2 TP: 2.2’-dipyridine (differentiation between Fe2+ and Fe3+ possible) analog DIN 38406E1 and US Standard Method 3500-Fe LD; Model FE-1 TP: TPTZ
Applications:
Wastewater, drinking water, foodstuffs
Note:
For the determination of total iron crack set 10 and empty round cuvettes or Crack-Set 10-C are required (120 °C, 1 h)
Photometric test kit for measurement of Iron Fe
Available ranges:
0.005 - 5.00 mg/l Fe
Number of tests: 250 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.05 - 3.00 mg/l Fe
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models 14549 and 14761: Triazine. Model 14896, Model FE-2 TP: 2.2’-dipyridine (differentiation between Fe2+ and Fe3+ possible) analog DIN 38406E1 and US Standard Method 3500-Fe LD; Model FE-1 TP: TPTZ
Applications:
Wastewater, drinking water, foodstuffs
Note:
For the determination of total iron crack set 10 and empty round cuvettes or Crack-Set 10-C are required (120 °C, 1 h)
Photometric test kit for measurement of Copper Cu
Available ranges:
0.02 - 6.00 mg/l Cu
Number of tests: 250 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 0.04 - 6.00 mg/l Cu
Additional information:
Reference CombiCheck test available.
Reaction:
Cuprizon. Model Cu-1 TP: Biquinoline
Applications:
Wastewater, drinking water, ground water, foodstuffs
Note:
Crack set 10 and empty round cuvettes or Crack set 10-C are required for the determination of total copper (100 °C or 120 °C, 1 h)
Photometric test kit for measurement of Nickel Ni
Available ranges:
0.02 - 5.00 mg/l Ni
Number of tests: 250 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
Additional information:
Reference CombiCheck test available.
Reaction:
Dimethylglyoxime, analog to DIN 38406 E11
Applications:
Wastewater, drinking water, surface water
Note:
For the determination of total nickel crack set 10 and empty round or Crack-Set 10-C are required (120 °C, 1 h)
Testing aid for pipette volume