Empty cuvettes for laboratory turbidimeter Turb 550, Turb 550 IR, Turb 555 and Turb 555 (IR) Delivery: 6 pcs
Wide-range power supply 100 to 240 V, 50/60 Hz for inoLab, 3xxi, 197i
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M 256 for meters to be used at waste water treatment plants
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 50 um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* Especially suitable for use in denitrification and for oxygen addition measurements
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 25um special membrane
- Extremely short response time
- Low incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 30 seconds
Sensor length:
- 196mm
Connection cable:
- 7m, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Zero current free electrode system
- Exchangeable membrane head with robust 50um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60 mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP65)
Type of protection:
- IP 68 (sensor)
Single Unit Including Accessories BNC-inlet. The WTW inoLab® pH 7110 Benchtop Meter is highly suitable for routine measurements in the lab, where automatic documentation is not a priority. Less keys makes operation simple and safe with smooth, easy to clean surface.
Technical buffer solution, 1 bottle with 1 l : pH 2.0
Technical buffer solution, 1 bottle with 50 ml: pH 4.01
Technical buffer solution, 1 bottle with 50 ml: pH 7.00
Cleaning head for online sensors
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
- CH cleaning head for online sensors with a shaft diameter of 40 mm
- The cleaning is done by means of external compressed air;
- The compressed air supply is controlled via a separate, electrically operated valve
- It is time-controlled by a relay of the series 170/296 measuring transmitters or the IQ SENSOR NET
The external compressed air supply can be provided via a compressed air line or a compressor
Requirements for this:
- dry compressed air
- free of oil and dust
- 3-7 bar
- approx. 40 NL/min
Photometric test kit for measurement of Chromate (chromium VI and total chromium Cr)
Available ranges:
0.05 - 2.00 mg/l Cr
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.05 - 2.00 mg/l Cr
Additional information:
For use with seawater.*
Reaction:
Diphenylcarbazide
Applications:
Wastewater, drinking water, *sea water: 14552 only chromate
Note:
Model 14552: contains all digestion reagents for total chromium. Model 14758: Crack set 10 and empty round cuvettes or Crack set 10-C are required for the determination (120 °C, 1 h)
Photometric test kit for measurement of Chromate (chromium VI and total chromium Cr)
Available ranges:
0.01 - 3.00 mg/l Cr
Number of tests: 250 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
For use with seawater.
Reaction:
Chromosulfuric acid oxidation, analog to EN ISO 15705
Reaction:
Diphenylcarbazide
Applications:
Wastewater, drinking water, *sea water: 14552 only chromate
Note:
Model 14552: contains all digestion reagents for total chromium. Model 14758: Crack set 10 and empty round cuvettes or Crack set 10-C are required for the determination (120 °C, 1 h)