Photometric test kit for measurement of Aluminium Al
Available ranges:
- 0.02 - 0.50 mg/l Al
Number of tests: 25 (Reaction cuvettes test)
- Sample volume required: 6ml
- Cuvette type: round
Compatible with photometers:
- photoLab S12
- photoLab Spectral
- pHotoFlex
Additional information:
- Reference CombiCheck test available.
Reaction:
- Chromazurol S, analog EN ISO 10566 E30, US Standard Methods 3500-Al D, Model AI-1 TP: Eriochromcyanin R analog US Standard Method 3500-AL D, ISO 10566 E30
Applications:
- Ground-, surface-, sea-, wastewater, drinking water, seepage water, process water
Photometric test kit for measurement of Ammonium NH4
Available ranges:
0.20 - 8.00 mg/l NH4-N
0.26 - 10.3 mg/l NH4+
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.20 - 8.00 mg/l NH4-N; 0.26 - 10.3 mg/l NH4+
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Indophenol blue (Berthelot reaction) analog to DIN 38 406 E5/ISO 7150. Models NH4-x: Salyticate
Applications:
Wastewater, drinking water, sea water
Calibration kit for turbidimeter Turb 555, 0.02 - 10.0 - 100 - 1750 NTU, cleaning tissues and indexing rings
Photometric test kit for measurement of Phenol C6H5OH
Available ranges:
0.10 - 2.50 mg/l C6H5OH
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
For use with seawater.
Reaction:
4-Amoniantupyrin analog ISO 6439 / US Standard Methods 5530, EPA 420.1 (00856); SMBTH (14551)
Applications:
Wastewater, surface water
Photometric test kit for measurement of Phosphate PO4
Available ranges:
0.5 - 25.0 mg/l PO4-P
1.5 - 76.7 mg/l PO4
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.5 - 25.0 mg/l PO4-P; 1.5 - 76.7 mg/l PO4
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Nitrate NO3
Available ranges:
0.1 - 25.0 mg/l NO3-N
0.45 - 110.7 mg/l NO3
Number of tests: 90 (Reagent tests)
Sample volume required: 0.5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reference CombiCheck test available.
Reaction:
Model 14542 and 14773: nitrospectral; Models N1/25, 14764, 09713 and 00614: DMP analog to DIN 38405 D9/ISO 7890;
Models 14556 and 14942: phenol derivative (suitable for sea water); Model NO3-1 TC: chromotrope acid
Applications:
Wastewater, drinking water, surface water; Model 00614: also for nutrient solutions for fertilization, soils
Note:
Models 14773 and 09713: For the determination of total nitrogen Crack Set 20 and empty round cuvettes are required
For N2/25 CombiCheck 20 can be used.
Photometric test kit for measurement of Nitrite NO2
Available ranges:
0.005 - 1.000 mg/l NO2-N
0.016 - 3.29 mg/l NO2
Number of tests: 335 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 0.01 - 0.50 mg/l NO2-N; 0.03 - 1.64 mg/l NO2
Additional information:
For use with seawater.
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation
Photometric test kit for measurement of Nitrite NO2
Available ranges:
0.005 - 1.000 mg/l NO2-N
0.016 - 3.29 mg/l NO2
Number of tests: 1000 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 0.01 - 0.50 mg/l NO2-N; 0.03 - 1.64 mg/l NO2
Additional information:
For use with seawater.
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation
Photometric test kit for measurement of Phosphate PO4
Available ranges:
0.5 - 30.0 mg/l PO4-P
1.5 - 92.0 mg/l PO4
Number of tests: 400 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Chloride Cl
Available ranges:
2.5 - 250 mg/l Cl
Number of tests: 100 (Reagent tests)
Sample volume required: 1, 5ml
Cuvette type: 10mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 10 - 190 mg/l Cl
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Iron(III)-thiocyanate analog DIN 38405 D31
Applications:
Waste water, drinking water, ground water, mineral water / after dilution
Photometric test kit for measurement of Phosphate PO4
Available ranges:
3.0 - 100.0 mg/l PO4-P
10.0 - 307.0 mg/l PO4
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 0.2ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 3.0 - 70.0 mg/l PO4-P; 10.0 - 214.0 mg/l PO4
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Molybdenum Mo
Available ranges:
0.02 - 1.00 mg/l Mo
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Model 00860: Brompyrogallolrot; Model Mo-1 TP: Thioglycol acid
Applications:
Nutrient solutions for fertilization, process solutions, boiler water and boiler feed water, waste water