Photometric test kit for measurement of Phosphate PO4
Available ranges:
3.0 - 100.0 mg/l PO4-P
10.0 - 307.0 mg/l PO4
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 0.2ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 3.0 - 70.0 mg/l PO4-P; 10.0 - 214.0 mg/l PO4
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Molybdenum Mo
Available ranges:
0.02 - 1.00 mg/l Mo
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 10ml
Cuvette type: round
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Model 00860: Brompyrogallolrot; Model Mo-1 TP: Thioglycol acid
Applications:
Nutrient solutions for fertilization, process solutions, boiler water and boiler feed water, waste water
Photometric test kit for measurement of Phosphate PO4
Available ranges:
1.0 - 100.0 mg/l PO4-P
3.0 - 307.0 mg/l PO4
Number of tests: 100 (Reagent tests)
Sample volume required: 8ml
Cuvette type: 10mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 1.0 - 50.0 mg/l PO4-P; 3.0 - 153.0 mg/l PO4
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Phenol C6H5OH
Available ranges:
0.002 – 0.100 mg/l C6H5OH
0.025 – 5.000 mg/l C6H5OH
Number of tests: 50250 (Reagent tests)
Sample volume required: 20010ml
Cuvette type: round
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
For use with seawater.
Reaction:
4-Amoniantupyrin analog ISO 6439 / US Standard Methods 5530, EPA 420.1 (00856); SMBTH (14551)
Applications:
Wastewater, surface water
Photometric test kit for measurement of Phosphate PO4
Available ranges:
0.05- 5.00 mg/l PO4-P
0.05 - 5.0 mg/l PTotal*
0.2 - 15.3 mg/l PO4
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.05- 5.00 mg/l PO4-P; 0.05 - 5.0 mg/l PTotal*; 0.2 - 15.3 mg/l PO4
Additional information:
Reference CombiCheck test available.
For use with seawater. *
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Phosphate PO4
Available ranges:
0.5 - 25.0 mg/l PO4-P
0.5 - 25.0 mg/l PTotal*
1.5 - 76.7 mg/l PO4
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 1ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.5 - 15.0 mg/l PO4-P; 0.5 - 15.0 mg/l PTotal*; 1.5 - 46.0 mg/l PO4
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometric test kit for measurement of Chloride Cl
Available ranges:
- 2.5 - 250 mg/l Cl
Number of tests: 175 (Reagent tests)
- Sample volume required: 1, 5ml
- Cuvette type: 10mm
Compatible with photometers:
- photoLab S12
- photoLab Spectral
- pHotoFlex 10 - 190 mg/l Cl
Additional information:
- Reference CombiCheck test available.
- For use with seawater.
Reaction:
- Iron(III)-thiocyanate analog DIN 38405 D31
Applications:
- Waste water, drinking water, ground water, mineral water / after dilution
Photometric test kit for measurement of Nitrate NO3
Available ranges:
- 0.1 - 25.0 mg/l NO3-N
- 0.45 - 110.7 mg/l NO3
Number of tests: 250 (Reagent tests)
- Sample volume required: 0.5ml
- Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
- photoLab S12
- photoLab Spectral
Additional information:
- Reference CombiCheck test available.
Reaction:
- Model 14542 and 14773: nitrospectral; Models N1/25, 14764, 09713 and 00614: DMP analog to DIN 38405 D9/ISO 7890;
- Models 14556 and 14942: phenol derivative (suitable for sea water); Model NO3-1 TC: chromotrope acid
Applications:
- Wastewater, drinking water, surface water; Model 00614: also for nutrient solutions for fertilization, soils
Note:
- Models 14773 and 09713: For the determination of total nitrogen Crack Set 20 and empty round cuvettes are required
- For N2/25 CombiCheck 20 can be used.
Empty cuvettes for portable turbidimeter Turb 350 / 355 IR and 355 T Delivery: 6 pcs
Precision pH combination electrode, with glass shaft, spherical membrane and liquid electrolyte
The SenTix® 91 is ideal for pH measurements in lab applications
Specifications:
Model: SenTix 91 pH Probe
Body material: Glass
Electrolyte: Liquid electrolyte
Membrane: Spherical
Length: 170mm
Cable: DIN
Cable Length: 1 meter
Refillable: Yes
Temperature Sensor: Yes, NTC 30 kW
Waterproof: No
Pack: Pack of 1
SenTix® Range: Standard electrodes with gel and precision electrodes with liquid gel electrolyte for pH measurements in lab applications and in the field
Nitrate armature with temperature measurement, nitrate replacement electrode, nitrate reference electrode and compensation electrode
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Digital nitrate sensor
- For connection to the IQ SENSOR NET multiparameter measuring system
- With integrated temperature sensor
Equipped with the following features:
- Integrated lightning protection
- Sensor with integrated preamplifier for low impedance signal transmission
- Thermistor system for temperature compensation
- Calibration via specific calibration menus
- With screw / plug connector for connection of the SACIQ sensor connection cable
- Use with automatic compressed air cleaning recommended (MIQ/CHV magnetic valve module as well as CH cleaning head required for the systems 184 XT/ 2020 XT or DIQ/CHV for the system 182)
Length of armoring:
- 392 mm (incl. adapter of the sensor connection cable)
Material:
- Sensor head /protective hood: PVC/POM
- Enclosure shaft: V4A stainless steel 1.4571
Type of protection:
- IP68, (with the SACIQ sensor connection cable connected)
Pressure resistance:
- Armature with installed electrodes: max. 0.2 bar overpressure
Power consumption:
- 0.2 watt
Technical buffer solution, 1 bottle with 50 ml: pH 10,01