Photometric test kit for measurement of Phosphate PO4
Available ranges:
0.01 - 5.00 mg/l PO4-P
0.03 - 15.3 mg/l PO4
Number of tests: 420 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.20 - 2.50 mg/l PO4-P; 0.60 - 4.60 mg/l PO4
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Field case with table insert to hold instrument, stand and cuvettes for easy field handling. Additional space to hold accessories and pipette
Photometric test kit for measurement of Ammonium NH4 Available ranges:
Number of tests: 200 (Powder Pillows)
Sample volume required: 10ml
Compatible with photometers:
pHotoFlex 0.00 - 0.50 mg/l NH4-N; 0.00 - 0.64 mg/l NH4
Additional information:
Reaction:
Indophenol blue (Berthelot reaction) analog to DIN 38 406 E5/ISO 7150. Models NH4-x: Salyticate
Applications:
Wastewater, drinking water, sea water
AOX Standard Solution, volume: 85ml (8-16 Checks), concentration: 20mg/l, model type: AOX 00680
BOD Standard Solution, volume: 10 bottles for 10 x 1lml, concentration: 210mg/l, model type: BOD 00718
Photometric test kit for measurement of Phosphate PO4
Available ranges:
- 0.01 - 5.00 mg/l PO4-P
- 0.03 - 15.3 mg/l PO4
Number of tests: 220 (Reagent tests)
- Sample volume required: 5ml
- Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
- photoLab S12
- photoLab Spectral
- spectroFlex
- pHotoFlex 0.20 - 2.50 mg/l PO4-P; 0.60 - 4.60 mg/l PO4
Additional information:
- Reference CombiCheck test available.
- For use with seawater.
Reaction:
- Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
- Models 14546, 14842: vanadate-molybdate (VM)
Applications:
- Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
- The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Calibration kit for turbidimeter Turb 555 IR: 0.02 - 10.0 - 100 - 1750 NTU, cleaning tissues and indexing rings
The Pure Water Conductivity probe is used for the testing of ultra-pure water and low conducting solutions. The two electrode measuring cells are concentric electrodes of stainless-steel and flow vessels which are made of glass or stainless-steel for the measurement of ultra-water. It has a built-in temperature sensor and waterproof plug. This probe can be used with a variety of meters including: Cond 315i, LF 320/323/325, LF 330/340A, Cond 330i/340i, inoLab Cond pH/Cond and Multi, LFF 538, MultiLab 540, Multi 350i, LF 197, LF 597 and the Cond 197i. Key Features:
Cleaning solution for galvanic oxygen sensors:
- StirrOx® G
- CellOx®325
- DurOx 325
- TA 197 Oxi
- ConOx
- MPP 350 D.O. module
1 bottle with 30ml
Lead Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Pb 19776
Iron Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Fe 19781
Zinc Standard Solution, volume: 500ml, concentration: 1000mg/l, model type: SL Zn 19806