Photometric test kit for measurement of Sulfate SO4
Number of tests: 100 (Powder Pillows)
Sample volume required: 10ml
Compatible with photometers:
pHotoFlex 0 - 70 mg/l SO4
Additional information:
Reaction:
Models 14548, 14564 and 00617, SO4-1 TP: barium sulfate, turbidometric, analog US Standard Method 4500-SO42- E/IPA 375.4.; Model 14791: tannin
Applications:Ground water, building materials, soils
Photometric test kit for measurement of Chlorine Cl2
Number of tests: 100 (Powder Pillows)
Sample volume required: 25ml
Compatible with photometers:
pHotoFlex 0.00 - 2.00 mg/l Cl2, total
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Nitrate NO3
Number of tests: 50 (Cuvette Test)
Sample volume required: 2ml
Compatible with photometers:
pHotoFlex 0 - 30.0 mg/l NO3-N; 0.0 -133.0 mg/l NO3
Additional information:
Reaction:
Model 14542 and 14773: nitrospectral; Models N1/25, 14764, 09713 and 00614: DMP analog to DIN 38405 D9/ISO 7890;
Models 14556 and 14942: phenol derivative (suitable for sea water); Model NO3-1 TC: chromotrope acid
Applications:
Wastewater, drinking water, surface water; Model 00614: also for nutrient solutions for fertilization, soils
Note:
Models 14773 and 09713: For the determination of total nitrogen Crack Set 20 and empty round cuvettes are required
For N2/25 CombiCheck 20 can be used.
Photometric test kit for measurement of Nitrite NO2
Number of tests: 48 (Cuvette Test)
Sample volume required: 20,5ml
Compatible with photometers:
pHotoFlex 0.03 - 0.60 mg/l NO2-N (LR); 0.10 - 2.00 mg/l NO2 (LR); 0.30 - 3.00 mg/l; NO2-N (HR) 0.99 - 9.90 mg/l NO2
Additional information:
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation
Photometric test kit for measurement of Chlorine Cl2
Available ranges:
0.010 - 6.00 Cl2
Number of tests: 1200 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Chlorine Cl2
Available ranges:
0.010 - 6.00 Cl2
Number of tests: 200 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Chlorine Cl2
Available ranges:
0.010 - 6.00 Cl2
Number of tests: 200 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
25 cuvettes with digestion reagents for thermal digestion of heavy metals in wastewater analysis
Photometric test kit for measurement of Chlorine Cl2
Available ranges:
0.010 - 6.00 Cl2
Number of tests: 1200 (Reagent tests)
Sample volume required: 10ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Monochloramine
Available ranges:
0.05 – 10.0 mg/l Cl2
Number of tests: 150 (Reagent tests)
Sample volume required: ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Thymol
Applications:
Drinking water, waste water, disinfectants
Photometric test kit for measurement of Ammonium NH4
Available ranges:
- 0.010 - 3.00 mg/l NH4-N
- 0.013 - 3.86 mg/l NH4+
Number of tests: 250 (Reagent tests)
- Sample volume required: 5ml
- Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
- photoLab S12
- photoLab Spectral
- spectroFlex
- pHotoFlex 0.02 - 1.50 mg/l NH4-N; 0.03 - 1.93 mg/l NH4+
Additional information:
- Reference CombiCheck test available.
- For use with seawater.
Reaction:
- Indophenol blue (Berthelot reaction) analog to DIN 38 406 E5/ISO 7150. Models NH4-x: Salyticate
Applications:
- Wastewater, drinking water, sea water
Photometric test kit for measurement of Manganese Mn
Available ranges:
- 0.01 - 10.0 mg/l Mn
Number of tests: 250 (Reagent tests)
- Sample volume required: 5ml
- Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
- photoLab S12
- photoLab Spectral
- pHotoFlex 0.02 - 9.00 mg/l Mn
Additional information:
- Reference CombiCheck test available.
- For use with seawater.
Reaction:
- Formaldoxime, analog to DIN 38 406 E2. Model Mn-1 TP: Periodat-Oxidation analog US Standard Method 3500-Mn D
Applications:
- Wastewater, drinking water