The ProfiLine hand-held conductivity meter has a waterproof (IP 67) housing and a new, completely sealed silicone membrane keypad with tactile feedback. A separate battery compartment allows easy exchange of standard alkaline, or rechargeable, batteries. The carefully laid out, large displays indicate the reading and other important information. This meter is comfortable and versatile with integral, time controlled, data logger and 5000 GLP-compliant record memory for extended data collection. Menu controlled, with backlit, graphics display for comfortable, safe operation. Wide range of conductivity cells attachable. GLP-supporting functions, enhanced choice of cell constants, automatic and manual temperature compensation (which can be switched off) with linear and non-linear functions for pure water and natural waters acc. to EN 27888.
Reference electrolyte, 1 bottle with 250 ml KCl solution 3M/l
Photometric test kit for measurement of Water hardness, RH Residual hardness
Available ranges:
0.075 - 0.750 °d
0.50 - 5.00 mg/l Ca
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 4ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
Additional information:
Reaction:
Phthalein complexone
Applications:
Check of ion-exchanger plants for the production of deionized water
Photometric test kit for measurement of Ammonium NH4
Available ranges:
0.010 - 3.00 mg/l NH4-N
0.013 - 3.86 mg/l NH4
Number of tests: 500 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 0.02 - 1.50 mg/l NH4-N; 0.03 - 1.93 mg/l NH4
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Indophenol blue (Berthelot reaction) analog to DIN 38 406 E5/ISO 7150. Models NH4-x: Salyticate
Applications:
Wastewater, drinking water, sea water
Photometric test kit for measurement of Manganese Mn
Available ranges:
0.01 - 10.0 mg/l Mn
Number of tests: 500 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
pHotoFlex 0.02 - 9.00 mg/l Mn
Additional information:
Reference CombiCheck test available.
For use with seawater.
Reaction:
Formaldoxime, analog to DIN 38 406 E2. Model Mn-1 TP: Periodat-Oxidation analog US Standard Method 3500-Mn D
Applications:
Wastewater, drinking water
Suitable for test set model:
14739,
14752,
14537,
00613,
14560.
Photometric test kit for measurement of Hydrazine N2H4
Available ranges:
0.005 - 2.00 mg/l N2H4
Number of tests: 100 (Reagent tests)
Sample volume required: 5ml
Cuvette type: 10mm, 20mm, 50mm
Compatible with photometers:
photoLab S12
photoLab Spectral
Additional information:
Reaction:
4-Dimethylaminobenzaldehyde, analog to DIN 38413 P1
Applications:
Wastewater, drinking water, boiler feed water
Photometric test kit for measurement of Aluminium Al
Number of tests: 100 (Powder Pillows)
Sample volume required: 20ml
Compatible with photometers:
pHotoFlex 0.00 - 0.25 mg/l
Additional information:
Reaction:
Chromazurol S, analog EN ISO 10566 E30, US Standard Methods 3500-Al D, Model AI-1 TP: Eriochromcyanin R analog US Standard Method 3500-AL D, ISO 10566 E30
Applications:
Ground-, surface-, sea-, wastewater, drinking water, seepage water, process water
Photometric test kit for measurement of Chlorine Cl2
Number of tests: 100 (Powder Pillows)
Sample volume required: 10ml
Compatible with photometers:
pHotoFlex 0.00 - 2.00 mg/l Cl2, free
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Chlorine Cl2
Number of tests: 100 (Powder Pillows)
Sample volume required: 25ml
Compatible with photometers:
pHotoFlex 0.00 - 5.00 mg/l Cl2, free
Additional information:
Reaction:
DPD analog DIN 38408 G4, EN ISO 7393
Applications:
Disinfectants, wastewater, drinking water
Note:
Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When the measurement has been made the round cuvettes are emptied and cleaned for the next measurement. 00595, 00598/1 and 00598/2 are for the determination of free chlorine. 00597, 00599 are for the determination of free chlorine and total chlorine. 00602 is a test set for total chlorine determination. 200* = 100 Cl2 free + 100 Cl2 total
Photometric test kit for measurement of Manganese Mn
Number of tests: 100 (Powder Pillows)
Sample volume required: 10ml
Compatible with photometers:
pHotoFlex 0.0 - 20.0 mg/l Mn
Additional information:
Reaction:
Formaldoxime, analog to DIN 38 406 E2. Model Mn-1 TP: Periodat-Oxidation analog US Standard Method 3500-Mn D
Applications:
Wastewater, drinking water
Photometric test kit for measurement of Nitrite NO2
Number of tests: 100 (Powder Pillows)
Sample volume required: 10ml
Compatible with photometers:
pHotoFlex 0.00 - 0.33 mg/l NO2-N; 0.00 - 1.08 mg/l NO2
Additional information:
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation